17
POWER SUPPLY
The ATOM (Watch) utilizes 1 - 3 volt CR2430 Lithium Battery.
Transmitters use 1 - 3 volt, CR2 Lithium Battery. When used as a
Dive Computer, the ATOM's battery should provide over 100
dive hours of operation if 2 dives are conducted during each
dive period. The Transmitter's battery should provide over 1000
dive hours of operation.
Transmitters check battery voltage when they are pressurized and
will send a Low Battery signal to the Receiver in the ATOM when
the voltage drops below the Warning level. The ATOM checks
its battery voltage every 2 minutes during surface operation.
• If voltage of the ATOM decreases to the Warning level (2.75
volts), the Battery icon will appear (Fig. 4a) as an indication
that the Battery should be changed prior to commencing a
series of dives.
• If voltage decreases to the Alarm level (2.50 volts), the Battery
icon will flash and operation will revert to Main Time. The
ATOM would then operate in Watch modes until the Battery
becomes completely depleted.
• Battery Status cannot be checked during Dive Modes.
• If a Low Battery Condition was not displayed prior to starting
a Dive, and a Low Battery Condition occurs during the dive,
there will be sufficient Battery power remaining in the ATOM
to maintain it's operation for the remainder of that dive.