SET TURN PRESSURE ALARM (for Transmitter 1 only)
Information includes (Fig. 57A/B):
> Graphic TURN
> Set Point OFF or a numeric value, flashing.
> Symbol PSI (or M)
• Pressing and releasing the S button momentarily (< 2 sec-
onds) will step through the Set Points from OFF to 1,000 to
3,000 PSI (69 to 205 BAR) in 250 PSI (17 BAR) increments.
• Depressing and holding the S button will scroll through the
Set Points at a rate of 4 Set Points per second until it is
released.
• Pressing and releasing the A button momentarily (< 2 sec-
onds) will save the setting and/or advance to the SET END
PRESSURE ALARM screen with the Set Point flashing.
• Pressing and releasing the A button momentarily and repeat-
edly (< 2 seconds each time) will step through the other SET A
screens.
• Depressing the A and S buttons simultaneously for 2 seconds
will save the setting and revert back to the SET A screen.
• Depressing and holding the M button for 2 seconds will revert
to the Surface Mode screen.
• If no button is pressed during a period of 2 minutes, the unit
will revert to the Surface Mode screen.
Fig. 57B - Set Turn Pressure
Alarm (value)
Fig. 57A - Set Turn Pressure
Alarm (OFF)